Paragon Induced Draft Towers
Delta's Paragon® Induced Draft cooling tower design--available in single module capacities from 55 to 250 cooling tons--provides an extended, unrivaled lifecycle. No need to worry about replacements!
Standard Features
Experience Brilliance: PARAGON® Induced Draft Towers
• Seamless Engineered Plastic (HDPE) Shell
• Corrosion Proof Construction
• Direct Drive Fan System
• Totally Enclosed VFD Rated Motors
• Factory Assembled for Simple Installation
• 20-Year Shell Warranty
• Low Pressure Drop Self Propelled PVC Water Distribution System
• High Efficiency PVC Fill
• Made in the USA
Delta packed the PARAGON® Induced Draft Tower with features to make it stand out from the competition. It includes the only seamless exterior shell on the market! We mold the entire casing of the cooling tower as one-piece so there are no joints or seams to require maintenance or develop leaks. The durable shell is made of engineered plastic (HDPE) and is entirely corrosion-proof. This innovative feature minimizes your maintenance costs over time. It also allows our water cooling towers to handle the toughest water cooling jobs in any climate while featuring industry-leading 20-year warranty.
The tower's simple design reduces maintenance costs even further. We send your cooling tower from the factory fully assembled. This allows ease of use and more reliable service from day one. You can order your PARAGON® Induced Draft Tower in a wide range of cooling tower tonnage from 55 to 250 cooling tower tons. Choose the size that is perfect for your application!
As the technology leader among cooling tower manufacturers in USA, our advanced design translates into highly efficient and environmentally friendly cooling towers. Our goal is to provide the most trouble-free water cooling HVAC system you can buy. Get even more peace of mind with Delta’s 20-year warranty.
Detailed Features
Delta Cooling Towers Offer Cutting-Edge Engineering
All Delta Cooling Towers are factory assembled to the fullest extent possible for ease of installation and shipment. The following features are standard on our Paragon® Series Induced Draft Cooling Towers:
Shell: A seamless engineered polyethylene cylindrical (HDPE) molded shell, with conical transition for motor/fan assembly, louvered inlets and fitting orientation. Louvered inlets are designed for 360° air distribution. There are no joints, seams, panels, gaskets, bolts, fasteners or caulking like conventional towers.
Sump: Sump is integral with cooling tower shell, creating a one-piece seamless structure.
Water Distribution System: A self-propelled PVC distribution system incorporating a rotating sprinkler head and lateral distribution arms with integral drift eliminators. An inspection port is provided in the cooling tower shell at the lateral arm elevation for adjustment. (Non-rotating water distribution system is also available).
Wet Decking: A continuous wrapped spiral configuration of lightweight PVC, bonded and packed for maximum film cooling efficiency.
Fan Assembly: The fan assembly consists of a fan ring, propeller, motor and guard. The fan ring is coated with premium plasite coating ideal for the harshest corrosive environments. An adjustable pitch propeller fan, fiberglass reinforced polypropylene with a silica alloy hub, is directly driven by a totally enclosed VFD Premium rated motor designed for cooling tower duty. A fan guard is included that allows protection from the propeller and access to the motor.
Motor: Totally enclosed air over (TEAO) VFD rated motor with 1.15 service factor, designed for 208 or 230/460V 3 phase 60 cycle operation and suitable for outdoor service. Motor is provided with a 5-year motor manufacturer’s warranty.
Fitting Connections: PVC fittings are provided for inlet, outlet, overflow, drain
Hardware: All fasteners are 304 stainless steel. Anchor and lifting lugs are aluminum.
Get Up-to-Speed on Water Cooler Towers
Overview of Water Cooling Towers
Water cooling towers are used to cool machinery whether it is the condenser loop in a HVAC chiller or an industrial process machinery that generates heat and needs to be cooled to remain operating. Many applications on the HVAC side include large office buildings, hospitals and schools while on the industrial side applications include numerous manufacturing process industries, including chemicals, metals, plastics, pharmaceutical, oil, and nuclear.
The towers work by drawing air into the unit and cooling down the water through evaporating a portion of the water. The cooled water prevents your machinery from overheating and allows it to perform optimally. It also makes the atmosphere of your building more pleasant for everyone in a HVAC application.
Delta’s water cooling towers come in a range of sizes, from relatively small rooftop units to towers that cool a large hospital. The Delta PARAGON® Induced Draft Tower ranges in size from 84" x 146" with a capacity of 55 cooling tons to a size of 114" x 210" with a capacity of 250 tower tons.
Practical Applications of a Cooling Tower
In some industries, such as the nuclear power industry, cooling towers are essential to maintaining the nuclear reactor from overheating. This prevents your machines from overheating, shutting down, needing costly repairs and stopping production of an expensive product. A cooling tower is a vital investment in the safety and extended lifecycle of your industrial machinery.
Why Choose Delta’s PARAGON® Induced Draft Towers?
We have been one of the leading cooling tower manufacturers in the USA for nearly 50 years. Our innovative water cooling designs have stood the test of time. Delta is the only company in the industry to manufacture a one-piece shelf, with no seams, rivets, or other weak points that might need to be repaired. This allows our water cooling towers to be more durable and able to withstand the harshest elements.
While we continue to improve our products, we continue to use the same quality and attention to detail we've always had. We specialize in producing highly efficient and environmentally friendly cooling towers. Our induced draft cooling tower comes with a 20-year warranty that includes shell replacements and more. If you are ready to work with the technology-leading cooling tower suppliers, give us a call. We are always happy to help you find the best product for your industrial or commercial property.
The Difference between Natural Draft, Induced Draft, & Forced Draft Cooling Towers
There are a few different types of cooling towers. These include natural draft cooling towers, induced draft cooling towers, and forced draft towers. Natural draft towers use the principle that heat rises and feature a stack design to allow heat to escape the building while circulating cooler air back into the building. Induced draft cooling towers use fans to pull the hot air from the building and water to cool it. Forced draft cooling also uses a fan to draw hot air out of the building, but the fan is generally outside the building and circulates the air from bottom to top.
Top-Notch Service from Cooling Tower Experts
In addition to being the technology-leading manufacturer of quality water cooling towers, Delta has an experienced staff to assist you in your application. In fact, we pride ourselves on providing the best customer service. Delta’s service is unrivaled compared to other cooling tower suppliers. Our trained team of experts has the knowledge to help you identify the right cooling tower solutions for your business.
- Delta Cooling Tower Product Brochure
- Paragon Installation & Operation Manual
- Paragon Specification
- T55i & T70i & T85i Assembly
- T55i & T70i & T85i Fixed Nozzle Distribution Assembly
- T100i & T125i Assembly
- T100i & T125i Fixed Nozzle Distribution AssemblyT-55i through T-125i Layout
- T150i & T175i Assembly
- T150i & T175i Fixed Nozzle Distribution Assembly
- T-150i & T-175i Layout
- T200i & T250i Assembly
- T200i & T250i Fixed Nozzle Distribution Assembly
- T-200i & T-250i Layout
- /wp-content/uploads/D80755-Layout.pdf